RS485 INTERFACE CARD – 4 CONVENTIONAL ZONES (K545)

RS485 interface card used to connect and monitor up to four conventional fire detection zones to Kentec Syncro / Kentec Taktis control panels (compatible with Hochiki ESP protocol), also incorporating two sounder outputs and relay contacts.

Certified for use within systems compliant with EN 54 standards and often UL/FM approved (subject to overall system configuration).

Guarantee safe & secure checkout

🔥 RS485 Interface Card – 4 Conventional Detection Zones

Model: Kentec Syncro 4 Way Conventional Detection Zone Module
Compatible Panels: Kentec Syncro / Kentec Taktis
Protocol Compatibility: Hochiki ESP


📌 General Description

The RS485 4-Zone Conventional Detection Module is designed to interface up to four conventional fire detection zones with Kentec Syncro or Taktis addressable fire alarm control panels.

The module communicates via RS485 serial bus, allowing conventional detection circuits to be integrated into a fully addressable fire alarm system. It provides supervised inputs and outputs, making it ideal for mixed (hybrid) installations where conventional devices must be connected to an addressable control panel.

This module can effectively replace a standalone conventional panel when connected to the RS485 communication network of the main control panel.


🛠️ Main Technical Features

🔹 Detection Zone Inputs

  • 4 fully supervised conventional detection zones

  • Up to approximately 30 conventional detectors per zone (depending on system design)

  • Open circuit and short circuit monitoring

  • Alarm and fault status reporting to the control panel


🔹 Sounder Outputs

  • 2 supervised sounder circuits

  • Monitored for open/short circuit faults

  • Controlled directly by the main fire alarm panel


🔹 Relay Outputs

  • Volt-free (dry contact) relay outputs including:

    • Fire relay

    • Fault relay

  • Additional monitoring input for local power supply fault


🔹 Communication & Networking

  • RS485 serial communication interface

  • Bi-directional communication with the main panel

  • Up to 32 modules per RS485 network

  • Allows expansion up to:

    • 128 conventional zones

    • 64 sounder outputs (depending on system configuration)


🔹 Indications & Control

  • Individual LED indicators for:

    • Zone alarm

    • Zone fault

    • Sounder status

  • Fully programmable via the main Syncro/Taktis panel


📦 Compatibility

  • Designed for use with Kentec Syncro and Taktis fire alarm control panels

  • Compatible with Hochiki ESP protocol systems

  • Suitable for integration into hybrid conventional/addressable fire alarm systems


📜 Certifications & Standards

  • Designed for use in systems compliant with EN 54 standards (when installed as part of a certified Kentec system)

  • Commonly used in installations requiring compliance with UL/FM standards (subject to system configuration and approval)


⚙️ Typical Applications

  • Upgrading existing conventional systems to addressable platforms

  • Hybrid fire alarm installations

  • Expansion of existing Syncro/Taktis panels

  • Industrial, commercial, and large building applications